GATE CE 2025 (S2) — Question 57

Foundation EngineeringDeep foundations – static formulae, axial load capacity of piles in sands and clays, pile load test, pile under lateral loading, pile group efficiency, negative skin frictionNAT2 marksMedium

A 4 × 4 group pile, with each pile 20 m long and 500 mm in diameter, is installed in a square pattern in a clayey soil, as shown in the figure. The average unconfined compressive strength of the soil is 100 kN/m\(^2\), and the adhesion factor is 0.8. Neglect the bearing at the tip of the piles. For a group efficiency factor of 1.0, the centre to centre spacing \((s)\) of the piles (in m) would be ________ (round off to two decimal places).
Question image
Practise the full 2025-S2 paper
Challenge a friend: WhatsApp Telegram
From RENYXERAWhat rank do your marks get?GATE score, likely All-India Rank and qualifying marks for your category.
Practise more on Deep foundations – static formulae, axial load capacity of piles in sands and clays, pile load test, pile under lateral loading, pile group efficiency, negative skin frictionTimed, in the real exam interface · free to start