The 3-phase modulating waveforms (, and ), used in sinusoidal PWM in a Voltage Source Inverter (VSI) are
V
V
V
where rad/s is the fundamental frequency. The modulating waveforms are compared with a 10 kHz triangular carrier whose magnitude varies between +1 and −1. The VSI has a DC link voltage of 600 V and feeds a star connected motor. The per phase fundamental RMS motor voltage, in volts, is closest to
- A169.71
- B300.00
- C424.26
- D212.13