GATE ME 2021 (S1) — Question 59

Thermodynamicsapplication of first and second laws for analysis of closed and open systemsNAT2 marksMedium

An air-conditioning system provides a continuous flow of air to a room using an intake duct and an exit duct, as shown in the figure. To maintain the quality of the indoor air, the intake duct supplies a mixture of fresh air with a cold air stream. The two streams are mixed in an insulated mixing chamber located upstream of the intake duct. Cold air enters the mixing chamber at 5 °C, 105 kPa with a volume flow rate of 1.25 m\(^3\)/s during steady state operation. Fresh air enters the mixing chamber at 34 °C and 105 kPa. The mass flow rate of the fresh air is 1.6 times of the cold air stream. Air leaves the room through the exit duct at 24 °C.
Question image
Assuming the air behaves as an ideal gas with \(c_p\) = 1.005 kJ/kg.K and \(R\) = 0.287 kJ/kg.K, the rate of heat gain by the air from the room is ___________ kW (round off to two decimal places).
Practise the full 2021-S1 paper
Challenge a friend: WhatsApp Telegram
From RENYXERAPractise this subject in the exam simulatorTimed, GATE-style tests with analytics that find your weak topics.
Practise more on application of first and second laws for analysis of closed and open systemsTimed, in the real exam interface · free to start

A GATE question every morning

One real past-paper question every morning for your branch, answer hidden until you tap. Free on Telegram.

Join
Stuck? Ask in the student group